Cookie Consent by Free Privacy Policy website

Indicator VIS 100 HE


Download PDF

WEIGHT VISUALIZER for load cells

Indicator of weight with input for cargo cells or input 0-10V or 4-20mA.

Alphanumeric display to 5 characters / digits, height 100 mm, brightness automatically adjusted and suitable for external installation.

Container in stainless steel and watertight logons.

Configuration and calibration from remote control, serial trasmition Rs232, Rs485. RF868Mhz extern interface (optional).

Download installation and usage manual


Zoom Click to enlarge image

Indicator VIS 100 HE

Technical Specifications

Power supply100 - 240 V ac – 50 / 60 Hz
Max power consumption25 W
Operating temperature-10 / +40°C (14 °F / 104°F) Humidity maximum 85% non-condensing
Storage temperature-20 / +50°C (-4 / +122°F)
DisplayAlphanumeric 5-digit dot matrix 5 x 7 high-efficiency red LEDs with a wide viewing angle
 Reading distanceTill at 35 m
 Display brightnessAnti-reflection filter and automatic brightness adjustment in ambient light function. Suitable for direct light installation
Overall dimensions500 x 185 x 115 mm / 19.7 x 7.3 x 4.5 in (l x h x p)
MountingWall-mounted with 4 external side holes Ø 6,5 mm with center distance 510 x 155 mm (l x h)
Case materialStainless steel protected against dust
Protection levelIP 65
ConnectionsWaterproof circular connectors with conductor wiring with screw terminal
Power supply load cells5 V dc / 120 mA (maximum 8 cells with 350 Ω in parallel) protected against short-circuit
Linearity< 0.01% of full scale
Temperature deviation<0,0003% of full scale/°C
Internal resolution24 bit
Weight resolutionUp to 60,000 divisions on the load capacity
Measuring range-1.5 mV/V - +3.5 mV/V
Weight acquisition frequency6 Hz - 25 Hz
Digital filter0.2 Hz - 25 Hz
Number of weight decimalsfrom 0 to 3 decimal digit
Communication portsRS232c / RS485 standard; 4-key remote control for configuration and operational commands
 Max. cable length15m (Rs232c) and 1000m (Rs485)
 Serial protocolsASCII + programmable custom protocols
 Baud rateFrom 1200 to 115200 selectable
 Remote controlRemote control with 4 key for configuration and operating commands
 OptionsExternal 868 MHz RF interface, Ethernet protocol, Profibus protocol
Conforms to standardsEN61000-6-2, EN61000-6-3, EN61010-1
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeJ1 5 poles serial female
LengthND
1GND + Shield
2RS232 Rx
3RS485 -
4RS485 +
5RS232 Tx
TypeJ2 5 poles male load cell
LengthND
1+ Exc. Load cell
2+ signal load cell
3- Signal load cell
4- Exc. Load cell
5Shield
Connections  Indicator VIS 100 HE

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means